External flow control valve for confined installation conditions

In extremely confined installation conditions that prevent easy access to the flow control valve, an extension can be fitted to the housing and the flow control valve can be relocated to an externally accessible position.

A specially designed retrofit kit is available for each unit type.

The exhaust-side hose must be dimensioned according to the permissible air volume. A hose length of 1.5 m should not be exceeded.

If an incorrectly dimensioned hose diameter is used or the maximum length of 1.5 m is exceeded, the stroke frequency and therefore the conveying performance can be negatively affected, up to the point where the conveying principle of the TG units no longer functions.

Particular care must be taken to ensure that the hose cross-section of the extension is not selected too large. Different pressure conditions and flow velocities exist inside the unit. An incorrectly selected hose cross-section can cause the unit to become impaired or damaged after only a short period of operation because the flow differential required for safe operation is no longer ensured. In such cases, the slide can strike the housing.

A hose diameter that is too small can severely reduce the achievable conveying speed. When extending the exhaust air line, the required cross-sections and hose lengths must therefore be observed.

An incorrectly designed extension can lead users to increase the supply air pressure, which may damage the valve mechanism inside the unit.

Because the proper function of a hose extension always depends on the specific operating conditions on site, we do not provide warranty coverage for customer-designed extensions of the stroke adjustment. For our extension kits for the respective unit type, the spare-parts package contains instructions for correct installation and safe operation on site.

A customer-designed exhaust air extension may void the warranty!